BST-GR-005 Novel Passive Radiative Cooling Nano Coating
BST-GR-005 uses outer space as the cooling source, achieving a cooling effect below ambient temperature through efficient solar reflection and mid-infrared thermal radiation. Capatho utilizes the mechanism of high-infrared-emissivity nano powder structures that reflect sunlight and emit mid-infrared radiation, incorporating it into a hybrid material of aerogel, polymers, and nanoparticles, further processed into a coating product that can be easily applied to object surfaces. Once the coating is applied to a building, it can reflect most of the sunlight (reflectance greater than 95%), while effectively radiating heat to outer space in the mid-infrared range (emissivity greater than 95%), thereby achieving a “passive cooling” effect without requiring energy or refrigerants.
|
Item |
BST-GR-005 |
|
Appearance |
Uniform viscous fluid, without obvious particles or sediment |
|
Density(25℃) g/cm³ |
1.2±0.1 |
|
Viscosity (mPa·s), 25℃ |
Aerogel, nano titanium oxide/silicon oxide composite particles, modified inorganic resin, additives, deionized water, etc. |
|
|
|
|
Item |
BST-GR-005 |
|
Dry film thickness |
0.20mm |
|
Drying time(25℃,50% RH) |
Surface dry ≤ 2 h; hard dry ≤ 24 h |
|
Adhesion (cross-cut test) |
Class 0 (test substrate: coated galvanized steel plate) |
|
Solar reflectance (300-2500nm) |
0.95 |
|
Hemispherical emissivity |
0.95 |
|
Artificial aging resistance(1000h) |
No chalking, cracking, or peeling; solar reflectance decrease ≤ 2.3% |
|
Water resistance(168h) |
No blistering, wrinkling, or peeling |
|
Alkali resistance(48h) |
No abnormalities |
|
Cooling effect (compared to ambient temperature under sunlight) |
8-12℃ |
|
Service life |
8-10 years |
|
Lightness(L*) |
95 (standard white) |
|
Characteristics |
1. Light weight, thin coating, no additional building load, water-based, environmentally friendly, non-toxic.
|
BST-GR-005 can be widely applied to thermal insulation retrofitting of building exterior walls, ceilings, chemical pipeline insulation, granaries, oil storage tanks, and outdoor equipment unit housings.